There is absolutely no room for error in the detailing and installation of roofing and air sealing in these assemblies.
Unvented flat roof assembly.
Low slope and steep slope unvented roof systems i e.
An unvented roof assembly is constructed without any ventilation and is fully sealed on all sides and filled with insulation.
Four options for building an unvented roof assembly.
Condensing surface temperature controlled the thickness of the rigid insulation at both the roof deck and perimeter is determined by a calculation procedure similar to figure 5.
Recent building codes only allow unvented roof assemblies for pitches 3 12 and greater irc 2015 section r806 5 2 7.
Martin s post focuses on the marketing of owens corning 039 s propink unvented attic insulation system.
This document provides a brief description of different types of unvented roof assemblies and the benefits of unvented roof construction.
Insulation and air barrier are applied directly to the underside of the roof deck are common in applications where designers are seeking cost effective and energy efficient roof assemblies.
By installing spf insulation spray in place insulation in lieu of mineral fiber insulation in the joist cavity of a flat roof or between rafters of a cathedral ceiling the assembly may perform the same as or better than that of a typical one and venting can be shown to be unnecessary.
These assemblies are created by eliminating ventilation openings and moving the thermal moisture and air control boundaries to the plane of the roof deck.
It s not and so code doesn t require r value ratios.
Read all of r806 5 carefully.
Figure 6 describes open cell spray foam as air permeable.
Yes unvented roof assemblies can be insulated with fiberglass a wufi post and not just in climate zones 2b amp.
If you don t want to use sips or nailbase there are four basic approaches.
Unvented flat roof assembly.
Unvented roof assemblies such as conditioned attics and unvented cathedral ceilings are becoming common in north american construction.
Drying of unvented roofing assemblies is by definition only provided to the interior.
The higher the interior moisture level the thicker the rigid insulation required.
This is a mis interpretation of the code.
In unvented flat or low slope roofs with parapets perform a full flood test to ensure leak free installation of roofing membrane.
Sc historically typical construction of homes in canada and the us have vented attics between the ceiling of the interior space and the roof.
The colder the climate the thicker the rigid insulation required.
In some climates it requires a vapor barrier.