Why plumbing air vents are important.
Vent pipe distance above roof.
It channels the exhaust gases to the vent and helps maintain proper atmospheric pressure in the waste system.
Where a roof is used for any purpose other than weather protection vents shall extend at least 7 feet above the roof and shall be properly supported.
Above the roof plumbing vent height.
The re vent is the only exception since it runs horizontally.
Your home s plumbing system is designed to efficiently remove water and waste.
However it needs to be at least six inches above your fixture s flood level to keep from getting wet.
Vent pipes should extend to outdoors above the building roof and should terminate vertically not less than 6 above the roof surface nor more than 24 and must be at least 12 from any vertical surface such as a nearby sidewall.
Vent pipes shall terminate not less than 6 inches above the roof measured from the highest point where the vent intersects the roof.
Its drainage and vent functions are actually two systems.
On a sink that would be either the rim or overflow hole.
The vent stack is the pipe leading to the main roof vent.
A note on the main drain.
When builders look only at the table without reading the text they find that a 2 inch diameter drain can run a maximum distance of 8 feet to the vent.
If the pipe is farther than 10 feet from the roof peak it must be 2 feet above the highest point of the roof within 10 feet.
In other words the highest point within a 10 foot circle of the pipe.
All other gas vents shall terminate not less than 2 feet 610 mm above the highest point where they pass through the roof and at least 2 feet 610 mm higher than any portion of a building within 10 feet 3048 mm.
They may also see that the slope column references 1 4 inch per foot but they are likely to assume that it s just reiterating the minimum allowable slope for a 2 inch drain.